Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM00015
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2016 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 01/04/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
| 01/06/2016 | ERIC NEWCOMB | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 01/06/2016 | ERIC NEWCOMB | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 01/06/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. GENERAL: PLEASE PROVIDE A VALUATION FOR THE LABOR AND MATERIALS FOR THIS PROJECT. 2. SHEET A02.00; SECTION D: PLEASE PROVIDE THE METAL STUD SPACING, DIAGONAL BRACING SIZE AND SPACING, AND THE CONNECTION OF THE METAL STUDS TO THE EXISTING STRUCTURE AND TO NEW METAL STUDS. 3. SHEET A02.00; SECTIONS B AND C: THE CITY OF TUCSON REQUIRES ALL LETTERING TO BE A MINIMUM OF 3/32' IN HEIGHT. PLEASE REVISE. 4. SHEET A09.100; PARTITION TYPE 1: PER THE IBC SECTION 1607.14, INTERIOR PARTITIONS MUST BE CAPABLE OF RESISTING A HORIZONAL LOAD OF 5 PSF. THE CEILING CAN NOT RESIST THIS LOAD. PLEASE PROVIDE DIAGONAL BRACING AT THE TOP OF THE WALL, INDICATING THE BRACING SIZE AND SPACING, AND THE CONNECTION OF THE BRACING TO THE EXISTING STRUCTURE ABOVE AND TO THE TOP OF THE PARTITION. 5. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 01/06/2016 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 01/06/2016 | ERIC NEWCOMB | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 01/06/2016 | ENEWCOM1 | WATER | REVIEW | Passed | |
| 01/06/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |