Permit Number: T16CM00001
Parcel: 133033950

Review Status: Completed

Review Details: CELL TOWER/ANTENNAS

Permit Number - T16CM00001
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2016 KEN BROUILLETTE FIRE REVIEW Approved
01/07/2016 MICHAEL ST. PAUL ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T16CM00001
9575 East Speedway Boulevard
Cell Tower (C-1)


TRANSMITTAL: January 7, 2016


COMMENTS: the following comments are relative to an application for a Special Exception relative to cell tower antenna modifications.

Provide the address for this site on the title sheet and adjacent to the title block on all sheets.

Provide the Special Exception decision letter. Demonstrate compliance, with the conditions stated in the letter, on the plans.

These plans must be approved by Peter McLaughlin of the Planning sectiom.
01/07/2016 PETER MCLAUGHLIN PLANNING-CITY HALL REVIEW Denied Provide detail showing antenna dimensions. The elevation drawing on sheet R-3 of the RLS/T-Mobile plan set shows a height at top of antennas of 48 feet with a antenna centerline of 42 feet above grade elevation, which calculates to a 12-foot (144 inch) antenna length. Per Special Exception condition #18 the maximum antenna length shall be 99 inches. The elevation drawing on the Larson Camouflage plan set sheet PF-2 shows antenna height of 45 feet. Revise one or the other for consistency and provide an antenna detail showing antenna dimensions (length, width, depth) for clarity and to determine compliance with Special Exception conditions.
01/15/2016 LOREN MAKUS ENGINEERING REVIEW Approved
01/15/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. GENERAL: PLEASE PROVIDE TWO SETS OF STRUCTURAL CALCULATIONS FOR THE CMU WALL (SHEET S-1).
2. GENERAL: A SPECIAL INSPECTION WAS ADDED FOR THE CMU WALL. PLEASE PROVIDE A SPECIAL INSPECTION CERTIFICATE FOR APPROVAL.
3. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
01/20/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the electrical plan review comments, also include a written response.
#1. Provide complete electrical drawings for submittal as required per City of Tucson Commercial Electrical Submittal Requirements. These requirements can be downloaded from, www.tucsonaz.gov/pdsd, go to Development and Permits, click on, Preparing Plans and Permit, then go to Preparing your Plans for a Building Permit, go to Commercial Permits, then to Commercial Plan Review, Electrical items #1 through #6.
Ref: 2012 IBC sec 107.2.1
01/29/2016 FRODRIG2 COMMUNICATIONS REVIEW Approved LETTER SENT TO RECORDS

Final Status

Task End Date Reviewer's Name Type of Review Description
02/01/2016 KROBLES1 OUT TO CUSTOMER Completed