Permit Number: T16BU01389
Parcel: 99999999B

Review Status: Completed

Review Details: BILLBOARD - BLDG30days

Permit Number - T16BU01389
Review Name: BILLBOARD - BLDG30days
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2017 GLENN MOYER ADMINISTRATIVE ADMIN REVIEW Reqs Change Below are comments on the authorized repair submittal for COT ID# 367 at 3127 East Speedway Boulevard (T16BU01389).

Sheet 1 of 3
No comments.

Sheet 2 of 3
1. In 4th paragraph of Scope of Work, specify number, spacing and size of nails that attach section rests to stringers (see Comment #2 below).

2. In 4th paragraph of Scope of Work clarify lateral retention system that “holds in” steel face panel sections, specifying existing parts and any proposed parts to be added, including nails (note that in previous submittal, the deletion of panel clips was accepted on the basis of not playing a panel support function and its original function having become obsolete; the lateral retention function that the panel clips appeared to have previously played and what substitutes for that function, however, was not addressed at that time).

3. In 6th paragraph of Scope of work specify the number spacing and sizes of screws and bolts attaching wood trim sections to stringers if the trim plays a lateral retention function for the steel face panel sections (see Comment #2 above).

Sheet 3 of 3
1. In Face Panel Attachment (Top View), clarify the function of the 16d nail depicted and whether it is existing or not, and whether it relates to Comment 21 on Sheet 2 of 3.

FIN.
12/08/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/07/2017 ARUIZ1 OUT TO CUSTOMER Completed