Permit Number: T16BU00410
Parcel: 107031750

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T16BU00410
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2016 MARTIN BROWN FIRE REVIEW Approved
03/18/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved March 18, 2016
FLOODPLAIN USE PERMIT NO.: T16OT00360
ADDRESS: 2475 N Jackrabbit Ave Tucson, Arizona 85745
PROPERTY OWNER: SLE Properties LLC
2475 N Jackrabbit Ave Tucson, Arizona 85745

The use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1669L, specifically described as:

A portion of Parcel 107-03-1750, PT of W224.29' SE4 SW4 LYG N of ADJ to DRGWY .82 AC SEC 34-13-13

For the purpose of demolishing an existing commercial building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 9 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the demolishing of the buildings, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from demolishing the commercial building within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and General site plan sheets for the demolition of the building, which are made part of this permit.
4) The proposed demolition must comply with best management practices and not track sediment offsite into the public right-of-way per the Stormwater Pollution Prevention Plan.
5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT00360 FOR INFORMATION PLEASE CALL 791-5550."
6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
7) Any additional future disturbance or construction of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
8) See the associated activity T16BU00410.
9) This permit is specific to the improvements for 2475 N Jackrabbit Ave as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.


This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Joel Kramer
ADDRESS: 5995 E Grant Suite 111 Tucson, AZ 85712
PHONE: 520-405-2716
CONTRACTOR: INDEVCO
ADDRESS: 5995 E Grant Suite 111 Tucson, AZ 85712
PHONE: 520-405-2716

(EXPIRATION DATE) Month: 03 Day: 18 Year: 2017

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
04/08/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
04/08/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
04/08/2016 SSHIELD1 OIP REVIEW Passed
04/08/2016 STEVE SHIELDS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/08/2016 CPIERCE1 OUT TO CUSTOMER Completed