Plan Review Detail
Review Status: Completed
Review Details: REZONING - ZE HEARING
Plan Number - T15SE00035
Review Name: REZONING - ZE HEARING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/03/2015 | MPADILL1 | COMMUNITY PLANNING | REVIEW | Completed | DEPARTMENT OF PLANNING & DEVELOPMENT SERVICES SE-15-35 Verizon - Mission Road MH-1 Zone, Special Exception Santa Cruz Area Plan and the Plan Tucson 7/28/15 MP This proposal is for a special exception use in the MH-1 Mobile Home zone, to allow a wireless communication facility (WCF). Site is developed with a mobile home park with 401 spaces on 71.50-acres. Proposed location of stealth canister antenna, monopole is centralized in proximity to the clubhouse pool area. The applicant is proposing to replace an existing twenty-two (22) foot tall private street light pole and replace it with a thirty-seven (37) foot tall monopole that will include two lights (single mount) to the monopole, two flush mounted antennas and a temporary microwave antenna. The ground equipment will be located within an open 5' X 10' lease area. Ground equipment is a single sunwest cabinet mounted to a pre-cast concrete slab. A ten foot wide access and utility easement will be provided from Mission Road, a scenic arterial street. Proposed monopole is approximately 1,100 feet east of Mission Road. The nearest residential (mobile home space) unit within the mobile home park is approximately fifty feet to the west. Surrounding Land Uses and Zoning-The surrounding land uses and zones are; to the north is zoned MH-1 development with a mobile home park; to the east is zoned R-1 developed with a single-family detached site built homes; to the south is zoned RV (Recreational Vehicle) and O-3 Office zone, developed with an RV Park and a religious facility respectfully; and to the west is zoned MH-1 and developed with a public school complex. Land Use Area Plan Summary-The site is within the bounds of the Santa Cruz Area Plan, however, no specific policy direction is provided for communication cell tower facilities. Policy direction is provided by Plan Tucson. Plan Tucson - Plan Tucson identifies this area in the Future Growth Scenario Map as a "mixed-use corridor" category. The Plan supports providing a higher-intensity mix of jobs, services, and housing along major streets. Plan Tucson, guidelines LT28.1.2, supports telecommunication facilities to be installed and maintained to minimize visual impact and preserve views. LT28.1.3 states that WCF to be designed with improved appearances of the above ground structures and utilities, and extend access to high-tech wireless communication facilities throughout the city. Analysis - The applicant is proposing to extend the height of the existing private light pole from 22 feet to 37 feet, adding 15 feet to the height. The stealth canister antenna, monopole will be 37 feet tall with two flush mounted antennas and one temporary microwave antenna. In addition the monopole will also have a single mounted light with two lighting elements as constructed on the previous light pole. The 5' X 10' open ground lease area will have one enclosed cabinet with a height of 5 feet. Location of the monopole and ground equipment is to be in a centralized area of the mobile home park and in the proximity of the clubhouse and pool area. Two existing trees in the immediate area will be kept in place and they measure 26 feet and 18 feet in height. The 28 foot tall tree is approximately 10 feet from the monopole and 5 feet from the ground equipment. Staff recommends these trees be protected in place during construction of monopole installation. Proposed location will have minor visibility from adjacent arterial streets and adjacent land use developments. On-site mobile home unit within the park is approximately fifty feet to the west of the proposed monopole. Staff acknowledges that it is difficult to disguise a monopole. Mitigation measures supported by staff include; antennas and other attachments to be painted to match the existing on-site light pole structures located within the clubhouse/pool area, which help minimize visual impacts. Given that the monopole will be disguised as a street lamp with two flush mounted antennas and the ground equipment is minimal in a 5' X 10' open lease area with a single cabinet at a height of five feet, the proposed monopole should not significantly change existing view sheds. The proposal is consistent with land use plan policies, and does not require a plan amendment. Staff will review plans for this proposal based on but not limited to location of the monopole and ground equipment on the site, color of monopole, massing and scale of antenna arrays, and compatibility of ground equipment. Interior streets of the mobile home park are private and will require a recorded egress-ingress access easement from the wireless communication facility to the Mission Road, the nearest public road. Recommendation: The request for special exception is consistent with policy direction provided by Plan Tucson and the Santa Cruz Area Plan. Staff offers the following design mitigation measures for consideration as part of the special exception process. 1. Wireless communication tower shall be disguised as a light pole located stealth canister antenna. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 2. The stealth canister antenna, monopole/lightpole shall not exceed 37 feet in height and located as shown on the preliminary development plan, dated 7/01/15. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 3. The stealth canister antenna, monopole/lightpole shall be similar in color to existing light poles within the clubhouse/pool area. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 4. Ground equipment lease area limited to a 5' X 10' open lease area with a single cabinet at a height of five feet, as shown on preliminary development plan, dated 7/01/15. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 5. The stealth canister antenna, monopole/lightpole shall include two light fixtures, as shown on preliminary development plan, dated 7/01/2015. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 6. Existing mature tree(s) adjacent to proposed monopole/lightpole shall be protected in place. Prior to construction and installation of monopole/lightpole and ground equipment, temporary fencing to be installed to protect tree(s). " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 7. The development package shall clearly illustrate compliance with all conditions through the use of details, diagrams and/or notes. " PT, Chapter 3, The Built Environment, Policy LT1 " PT, Chapter 3, The Built Environment, Set 1 All Developments, Guidelines - LT 28.1.2., and LT28.1.3 s:\caserev\SP-ECPT\SE5\ SE-15-35 Verizon _ Mission Road |
| 08/07/2015 | STEVE SHIELDS | ZONING | REVIEW | Completed | PDSD TRANSMITTAL TO: Planning and Development Services Department Rezoning Section FROM: Steve Shields Lead Planner PROJECT: Verizon Cell Tower - New Cell Site 4545 S. Mission Road, Parcel 119-420-06L - MH-1 Special Exception - SE-15-35 TRANSMITTAL: August 7, 2015 The proposed "Wireless Communication, limited to wireless communication towers and antennae", located on parcel 118-03-3250, zoned MH-1. The use falls under UDC Table 4.8-2 PERMITTED USES - URBAN RESIDENTIAL ZONES - Permitted as Special Exception Use, [1] Mayor and Council Special Exception Procedure, Section 3.4.4. The following Use Specific Standards apply: 4.9.4.I.2, .3 & .7. 1. The following dimensional Standards apply see TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES a. Minimum site area = 7,000 Sq. Ft b. Proposed site area = Not provided c. Maximum building height allowed = 25 feet d. Building height proposed = N/A e. Maximum Lot Coverage = 70% f. Proposed Lot Coverage = Not provided. If you have any questions about this transmittal, please call Steve Shields, (520) 836-4956 or email Steve.Shields@tucsonaz.gov. |
| 08/10/2015 | PMCLAUG1 | DOT ENGINEERING | REVIEW | Completed | |
| 08/10/2015 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Completed | |
| 08/10/2015 | PMCLAUG1 | ENGINEERING | REVIEW | Completed | DATE: July 1, 2015 DUE DATE: July 13, 2015 SUBJECT: Verizon Mission Road - Engineering Review LOCATION: 4545 S Mission Rd Rd REVIEWERS: Jason Green, CFM CASE #: SE-15-35 The PDSD Engineering Division has no objection to the Mayor & Council Special Exception (MCSE) and offers the following comments: 1. This request contains adequate information to determine plan compliance and plan amendment is not required. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 08/10/2015 | PMCLAUG1 | FIRE | REVIEW | Completed | |
| 08/10/2015 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Completed | |
| 08/10/2015 | PMCLAUG1 | ENV SVCS | REVIEW | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | PARKS & RECREATION | Completed | |
| 08/10/2015 | HEATHER THRALL | SIGNS | SIGN CODE REVIEW | Completed | Reviewer: H. Thrall Signs Division of Planning & Development Services 8/17/15 T15SE00035 For: proposed co-location of cellular arrays on light pole at residential mobile home park At: 4545 S Mission, Zoned RX-1, along Scenic Route = Scenic Corridor Zone District for Sign Code 1) No existing billboards on this property 2) Signage at this location subject to Scenic Corridor Zone District of the Sign Code (Mission Road is a Scenic Route and this property is within 400' of the scenic route). 3) No proposed signage shown on plans for cellular array box; should safety signage be required: - signs shall be a max of 2 square feet sign area each - shall not be illuminated - to be mounted to the cellular box - to contain only generic message (such as "Restricted area; electrified components") - shall not contain commercial advertisement. |
| 08/10/2015 | PMCLAUG1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA ASSN OF GOVTS | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA CNTY WASTEWATER | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | SCHOOL DISTRICT | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | ADOT | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT RTA | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT STREETS | Completed | |
| 08/10/2015 | PMCLAUG1 | REZ AGENCY REVIEW | OTHER AGENCIES | Completed |