Plan Number: T15PI00022
Parcel: Unknown

Review Status: Completed

Review Details: PIA - RESUBMITTAL

Plan Number - T15PI00022
Review Name: PIA - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2016 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change January 3, 2016


SUBJECT: Public Roadway Improvement Plans for Kinnison Overlook I-2015-019 T15PI00022

PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal.

1. Revise the Public Paving Plans to include a profile of the retention bleed pipe.

2. Revise the Public Paving Plans to include a dimensioned detail of the proposed basin outlet structure and outlet scour protection within the Kinnison Wash. The outlet structure must be designed to withstand flows from a 100 Yr. event within the Kinnison Wash. Provide all supporting hydraulic analysis for review.

3. Submit a PDF copy of the final approved soils report and drainage report.

4. Revise the Public Paving Plans to include a note indicating that the homowners association will be responsible for the maintenance of the bleed pipe.

5. Provide a pedestrian access easement for where the portion of sidewalk along Prudence Road that encroaches into common area "A-3". Contact Jim Rossi with the City's Real Estate Department for additional information. Mr. Rossi can be reached at (520) 837-6647 or at Jim.Rossi@tucsonaz.gov. Revise drawing to delineate and label easement with recordation number of easement.

If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsonaz.gov
01/08/2016 GARY WITTWER DOT LANDSCAPE REVIEW Denied You can not have private irrigation line under public roadway. Resubmit new irrigation design.
02/05/2016 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
02/05/2016 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
02/05/2016 ERNIE ENCINAS DOT_ELEC REVIEW Approved Traffic Maintenance - Electric Shop does not have any comments or conflict with the proposed improvements per Ernie Encinas 02/04/2016.
02/05/2016 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed
12/24/2015 JOSE ORTIZ DOT TRAFFIC REVIEW Approved
12/24/2015 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Completed
12/24/2015 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
12/24/2015 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Completed
12/24/2015 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Completed
12/24/2015 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
12/24/2015 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Denied
12/24/2015 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
12/24/2015 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Completed
12/24/2015 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Denied