Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T15PI00022
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2016 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | January 3, 2016 SUBJECT: Public Roadway Improvement Plans for Kinnison Overlook I-2015-019 T15PI00022 PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Revise the Public Paving Plans to include a profile of the retention bleed pipe. 2. Revise the Public Paving Plans to include a dimensioned detail of the proposed basin outlet structure and outlet scour protection within the Kinnison Wash. The outlet structure must be designed to withstand flows from a 100 Yr. event within the Kinnison Wash. Provide all supporting hydraulic analysis for review. 3. Submit a PDF copy of the final approved soils report and drainage report. 4. Revise the Public Paving Plans to include a note indicating that the homowners association will be responsible for the maintenance of the bleed pipe. 5. Provide a pedestrian access easement for where the portion of sidewalk along Prudence Road that encroaches into common area "A-3". Contact Jim Rossi with the City's Real Estate Department for additional information. Mr. Rossi can be reached at (520) 837-6647 or at Jim.Rossi@tucsonaz.gov. Revise drawing to delineate and label easement with recordation number of easement. If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsonaz.gov |
| 01/08/2016 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | You can not have private irrigation line under public roadway. Resubmit new irrigation design. |
| 02/05/2016 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 02/05/2016 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 02/05/2016 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | Traffic Maintenance - Electric Shop does not have any comments or conflict with the proposed improvements per Ernie Encinas 02/04/2016. |
| 02/05/2016 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 12/24/2015 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 12/24/2015 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied |