Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T15PI00022
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 10/27/2015 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 10/30/2015 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | Please submit the approved NPPO plan. I only received sheet 7 of the landscape plans. Please submit the landscape and irrigation plans. |
| 11/10/2015 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Approved | November 10, 2015 SUBJECT: Kinnison Overlook PIA Plan I-2015-019, DSD Activity #T15PI00022 PROJECT REVIEWER: Zelin Canchola, TDOT Review Section DOT Review Section has reviewed the PIA Plan for Traffic Engineering. Approval is granted. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 11/19/2015 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | November 17, 2015 SUBJECT: Public Roadway Improvement Plans for Kinnison Overlook I-2015-015 T15PI00019 PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Include the plan number "I-2015-019" in the title block of each sheet. 2. Include the PIA activity number "T15PI00022 on cover sheet. 3. Include complete details for the drainage improvements within the Kinnison Wash. Improvements must be designed to withstand flows during a 100yr event. Provide all hydraulic calculations for sizing structures. 4. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 11/25/2015 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 11/25/2015 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Needs Review | |
| 11/25/2015 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Needs Review | |
| 11/25/2015 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |