Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T15PI00014
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 06/29/2015 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 07/06/2015 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | The surface treatment for the median island on Ironwoodhills must be 4" thick concrete. We do not want landscaping in this median. Concrete finish should match medians on Silverbell. |
| 07/10/2015 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | July 10, 2015 SUBJECT: CVS Ironwood Hills Dr and Silverbell Rd Offsite Improvements. I-2015-009 T15PI00014 PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Include the plan number "I-2015-009" in the title block of each sheet. 2. Include the PIA activity number "T15PI00014 on cover sheet. 3. Label all the beginning and ending of horizontal curves for the proposed concrete curb. 4. Provide complete details for all for all proposed roadway infrastructure improvements associated with this development. 5. Indicate final surface treatment for median island; must match proposed Silverbell Rd improvements (I-2012-013). 6. Submit PDF copies of approved Development Package and revised paving plans with plan resubmittal. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 07/13/2015 | ZCANCHO1 | DOT TRAFFIC | REVIEW | Approved | |
| 07/22/2015 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 07/22/2015 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | July 22, 2015 Subject: CVS - Ironwood Hill Dr and Silverbell Rd Offsite Improvements, I-2015-009, T15PI00014 Project Reviewer: James Femling, TDOT Streets & Traffic Maint. Resubmittal Required: TDOT Streets & Traffic Maintenance Division has reviewed the subject PIA paving plan and does not recommend approval. Please refer to as-built set of plans for our irrigation in the area for your review. If you have any questions, I can be reached at James.Femling@tucsonaz.gov. |
| 07/22/2015 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |