Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2015 JOSE ORTIZ DOT TRAFFIC REVIEW Completed
05/04/2015 ESTEVAN TINEO DOT ENGINEERING REVIEW Denied 1. Include the proposed improvements along Broadway on this PIA plan.
2. Provide a standard type of access ramp at the nw corner of Leonora Ave and Broadway.
3. Detail how the existing median at Leonora will be modified to work with proposed raised median.
4. How will the proposed raised curbing impact existing drainage patterns?
5. Provide correpsonding profile view for proposed curbing.
6. How will proposed improvements impact existing monument structure located along the se corner of Leonora and 10th street?
7. Provide vertical curb to header transition for proposed radius curbing along Leonora and 10th.
8. Provide standard access ramp for proposed new curbing radius along Leonora and 10th.
9. Show existing traffic circle at the 10th and Leonora. How will curbing impact vehicular access at this intersection?
05/11/2015 GARY WITTWER DOT LANDSCAPE REVIEW Denied Is the new median island on Leonora a requirement? If it is installed and has landscape -the City can not maintain it and it will be the development's responsibility to maintain both the landscape and irrigation - this includes paying for water. Please submit landscape and irrigation plans on next submittal.

Note: private irrigation lines can not cross public roadways. Therefore you will be required to install a new meter and backflow in the median.

Please call me if you have questions - Gary 837-6618




GDW
05/14/2015 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Completed
05/14/2015 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
05/26/2015 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Needs Review Date: May 26, 2015
PROJECT NAME: Broadway Festival - Leonora Ave at Broadway Blvd
PLAN #: I-2015-004
ACTIVITY NUMBER: T15PI00008
PROJECT REVIEWER: James Femling, City of Tucson Transportation

Comments:

The TDOT Streets & Traffic Maintenance Division has reviewed the PIA Plan and recommends resubmittal. The following comment need to be addressed prior to submitting the mylar plan set for final approval.

1. C - Typical Road Section, STA 11+01.23 - STA 12+39.91 Sheet 3 - New 2" minimum overlay or chip & slurry seal.

If you have any questions, I can be reached at 791-3154 or James.Femling@tucsonaz.gov
05/26/2015 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
05/26/2015 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed