Plan Number: T15PI00007
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T15PI00007
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/13/2015 RICHARD LEIGH DOT ENGINEERING REVIEW Approv-Cond April 10, 2015

SUBJECT: Homegoods Distribution Center Corona Road Bus Pad U-2015-003- T15PI00007

PROJECT REVIEWER: Richard Leigh, DOT, DOT Eng. Review

RESUBMITTAL REQUIRED: TDOT Permits Section has reviewed the subject PIA paving plan and recommends a conditional approval at this time. The following comments need to be addressed prior to resubmittal of mylar plan set for final approval. Redlined drawings must be returned with subsequent submittal. Please reference PIA activity number on all correspondences.

1. Include the plan number "U-2015-003" in the title block of each sheet.
2. Include the PIA activity number "T15PI00007 on cover sheet.
3. Sheet 1 & 2: Depict and label City and county jurisdiction lines.
4. Sheet 1: Add a map showing the location and extent of work to be performed drawn to a scale of 1" = 100'.
5. Sheet 2: Revise drawing to clearly indicate the extent of the work to be performed with this plan set.
6. Sheet 2: Revise drawing to indicate the placement of a 22' long x 10' wide x 6" deep concrete bus pad.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
04/15/2015 JOSE ORTIZ DOT TRAFFIC REVIEW Reqs Change April 14, 2015


SUBJECT: Homegoods Distribution Center
PIA Plan U-2015-003, DSD Activity #T15PI00007

PROJECT REVIEWER: Zelin Canchola, DOT Review Section

RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. Resubmit with the following redlines on sheet 3 of 4

1. Add YS24 to Taper Striping

2. Add general notes for pavement marking symbol legends, pavement marking quantities and details if applicable from the Pima County/City of Tucson pavement marking design manual.

3. List quantities and descriptions.



If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov
04/20/2015 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Denied
04/20/2015 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
04/22/2015 GARY WITTWER DOT LANDSCAPE REVIEW Approv-Cond Will there be any planting or irrigation within the ROW. If so, please submit plans.
04/23/2015 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
04/23/2015 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
04/23/2015 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed