Permit Review Detail
Review Status: Active
Review Details: FLOODPLAIN
Permit Number - T15OT01631
Review Name: FLOODPLAIN
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/28/2015 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | March 30, 2016 FLOODPLAIN USE PERMIT NO.: T16OT01631 ADDRESS: 3060 N Campbell Avenue Tucson, Arizona 85719 OWNER: Global New Millennium Partners 4415 Highway 6, Sugar Land, Texas The use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1689L, specifically described as: A portion of Parcel 112-05-060B; Campbell Ave Acres W150' Lot 1 & PT N42.15' W150' Lot 2 Exc W10' and Spandrel in NW Corner Thereof BLK 5. For the purpose of constructing an elevated Commercial Building. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 8 conditions: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the layout of the buildings, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit is subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from construction of this commercial building. Demolishing the block wall on the east side of the parcel within the regulatory floodplain is a requirement of this permit and this permit will become invalid if this wall is not demolished or is rebuilt at any time. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) For purposes of this permit the following flood elevations shall be used for the enclosed shed: Base Flood Elevation (BFE) = 2386.5 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2387.5 feet NAVD 1988 Commerical Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the storage shed, if applicable, as well as the identity and location of all other equipment/machinery servicing the Commercial Building. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T15OT01631 FOR INFORMATION PLEASE CALL 791-5550." 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) All work shall conform to the approved site plan, T16CM02064, which is made part of this permit. 8) This permit is specific to the improvements for 3060 N Campbell Ave as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Metro Tucson Expediting and Development ADDRESS: 88 W Cushing Street, Tucson Arizona 85701 PHONE: 520-990-6866 CONTRACTOR: TBD ADDRESS: TBD PHONE: TBD (EXPIRATION DATE) Month: 03 Day: 30 Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/08/2015 | ANY | APPROVAL SHELF | RECEIVED |