Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T15OT01115
Parcel: 11105030F

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T15OT01115
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Reqs Change For compliance with floodplain regulations and Ordinance, (Tucson Code Chapter 26 Article I Section 26 and Technical manual Section 13-4), utility equipment must be elevated to at least one foot above the 100-year water-surface elevation. City of Tucson estimate for the regulatory flood elevation (RFE): BFE + 1 foot = 2405+1 = 2406. Clarify on plans compliance with RFE. Add note to plans that property is impacted by local jurisdictional floodplain. Clarify/add cross sections showing the elevated pad for the proposed structures (including shelter pad). Plans submitted indicate approximately a half of foot too low. - E Leibold P.E., CPM, CFM 837-4934

Final Status

Task End Date Reviewer's Name Type of Review Description
10/22/2015 FERNE RODRIGUEZ OUT TO CUSTOMER Completed