Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T15OT00652
Parcel: 118100210

Review Status: Active

Review Details: FLOODPLAIN

Permit Number - T15OT00652
Review Name: FLOODPLAIN
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
05/13/2015 LOREN MAKUS ENGINEERING REVIEW Approved May 13, 2015 (ELEVATION CERTIFICATES REQUIRED)

The applicant is authorized to use a portion of the flood hazard area (FEMA Zone AE, Panel 2278L) in the City of Tucson at 2640 South Cottonwood Lane Lot 21 for the purpose of installing a manufactured home.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the building or site improvements, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from new building and site improvements within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) All work shall conform to the attached plans (T15MH00028) which are made part of this permit.

3) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

4) For purposes of this permit the following flood elevations shall be used for the new structure:
Base Flood Elevation (BFE) = 2388.2 feet NAVD 1988
Regulatory Flood Elevation (RFE) = 2389.2 feet NAVD 1988
Building is to have lowest finished structural member elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached equipment such as air conditioning units is to be at or above the Regulatory Flood Elevation (RFE).

5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to finished construction or Final Inspection. The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the building as well as the identity and location of all other equipment/machinery servicing the building.

6) Any additional future disturbance of the floodplain including the construction of any fences, walls or accessory structures shall have separate floodplain use permit applications submitted to this office for review and approval.


This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.