Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - FLOODPLAIN
Permit Number - T15OT00594
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2015 | JASON GREEN | ENGINEERING | REVIEW | Approved | May 4, 2015 FLOODPLAIN USE PERMIT NO.: T15OT00594 ADDRESS: 2541 E Kleindale Rd Tucson, Arizona 85716 PROPERTY OWNER: Lori Pascarella The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1693L, specifically described as: A portion of Parcel 112-03-0260 For the purpose of installing new pool with associated electrical equipment. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, or local regulation. This floodplain use permit is issued with the following 8 conditions: 1) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 2) For purposes of this permit the following flood elevations shall be used for the elevation of associated pool equipment: Base Flood Elevation (BFE) = 2388.8 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2389.8 feet NAVD 1988 Pool equipment is to have the lowest point of any attached appliances at or above the Regulatory Flood Elevation (RFE). 3) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the pool. 4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T15OT00594 FOR INFORMATION PLEASE CALL 791-5550." 5) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 6) All work shall conform to the approved site plan, which is made part of this permit. T15BU00472. 7) This permit is specific to the improvements for 2541 E Kleindale Rd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Section. APPLICANT NAME: Valley Oasis Pools ADDRESS: 3321 N Freeway Tucson, Arizona 85705 PHONE: 520-881-2777 (EXPIRATION DATE) Month: 05 Day: 06 Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |