Permit Review Detail
Review Status: Active
Review Details: FLOODPLAIN
Permit Number - T15OT00430
Review Name: FLOODPLAIN
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2015 | JASON GREEN | ENGINEERING | REVIEW | Approved | June 10, 2015 FLOODPLAIN USE PERMIT # T15OT00430 PROJECT ADDRESS: 9408 E Pima Mine Road PROPERTY OWNER: City of Tucson Real Estate Division (Tucson Water) The applicant is authorized to use a portion of the mapped 100-year floodplain of the Lee Moore Wash per the Drainage Statement prepared by Westland Resources, Inc., 02APR15), specifically described as: Parcel 305-03-026B; NE4 NE4 NE4 10.00 AC SEC 34-16-15 The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 11 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes or further disturbance within the floodplain area occurs other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction activity within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved building plan package set which is made part of this permit. 4) For purposes of this permit the following flood elevation shall be used: Regulatory Flood Elevation (RFE) = 3083.5 feet NAVD 1988 Control Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the building as well as the identity and location of all other equipment/machinery. 6) Site surrounding the well head and the hydro pneumatic pressure tank foundation shall be graded to drain away from the structure. 7) The 5000 hydro pneumatic pressure tank is required to be anchored to prevent flotation, as shown on the approved plan set. 8) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 9) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 10) There shall be no stockpiling material, or storage of vehicles, other than that which is accepted by COT and as shown on the approved plans and SWPPP. There shall be no stockpiling or disturbance outside of disturbance limits. Construction material and vehicles shall be promptly removed once improvements are complete. 11) See the associated activity T15CM02070. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. APPLICANT: Westland Resources, Inc.; Attn: Mark Taylor ADDRESS: 4001 E Paradise Falls Dr Tucson, Arizona 85712 PHONE: (520)-206-9585 OWNER: Tucson Water ADDRESS: 310 W Alameda St Tucson, Arizona 85726 PHONE: (520)-837-2200 (EXPIRATION DATE) Month: 05 Day: 10 Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |