Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T15CM08910
Parcel: 126041600

Address:
920 N JERRIE AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T15CM08910
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/20/2016 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T15CM08910
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL COMMENTS:

1. Items built without permit may require alteration or improvement for achieving code compliance with the 2012 IRC, R101.3.
2. Show alterations (demo) at the existing kitchen to obtain the proposed bar (room 14) on sheet A1.0. Zoning has not approved a second kitchen for this property, or a duplex with separate address. Duplex units will have additional comments for fire separation and utility services.

FOUNDATION PLANS:

1. Show the minimum 12" footing depth below the undisturbed ground surface, R403.1 with #4 (top & bottom) continuous reinforcement. The continuous footing requirement applies to all new exterior walls. Update detail #1 & 2/S1.0.
2. Show anchor-bolts with minimum 7" embedment into concrete or masonry, R403.1.6. Update detail #1 & 2/S1.0.

STRUCTURAL PLANS:

1. Show the minimum thickness (1/2") of structural siding, R602.10.3.4, or the minimum hardboard sheathing thickness of 7/16", Table R703.4. Update sheathing details on sheet S1.0.

PLUMBING PLANS:

1. Show a minimum 1" service pipe rather than the ¾" shown at the conclusion of the Water Pressure Calc.
2. Tucson Water Department limits 5/8" water meters to a maximum of 11 IRC fixture units or 15 gallons per minute. Specify a ¾" water meter upgrade.
3. Show a drain pipe size for the clothes washer, Table P3005.4.1.
4. Show two clothes washer standpipes if installing gray water (note #14), City of Tucson Ordinance #11089.

MECHANICAL PLANS:

1. Provide heating facilities in all habitable rooms, R303.9. Show a duct size plan with demand calculations in accordance with Manual D standards, M1401.3.
2. Show supply ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, N1103.2.1. All other ducts outside of the thermal envelope require R-6 insulation.
3. Show dryer vent size and location for venting to exterior, M1501.

ELECTRICAL PLANS:

1. Show the location of panel C on the Electrical Plan, E3405.2, E3601.6.2 & E3705.8.
2. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
02/10/2016 FERNE RODRIGUEZ OUT TO CUSTOMER Completed