Permit Number: T15CM08704
Parcel: 124052410

Address:
419 N TYNDALL AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM08704
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2016 STEVE SHIELDS ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Steve Shields,
Lead Planner

PROJECT:
T15CM08704
419 N. Tyndall Avenue
New SFR

TRANSMITTAL: January 5, 2016

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 12'-9" the required perimeter yard setback to the west property line is 8'-6", proposed perimeter yard setback is 6'-0".

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).
Front Porch - based on a wall height of 9'-0" the required front street perimeter yard setback is 20'-0", proposed front street perimeter yard setback is 10'-11".
Main House - based on a wall height of 12'-9" the required front street perimeter yard setback is 20'-0", proposed front street perimeter yard setback is 18'-7".
01/11/2016 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review
01/11/2016 ELEIBOL1 ENGINEERING REVIEW Approved