Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T15CM08500
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/10/2015 | MARTIN BROWN | FIRE | REVIEW | Passed | |
| 12/18/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET S0.1: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE GENERAL CONSTRUCTION NOTES. 2. SHEET S2.1; FOUNDATION PLAN: A SLAB NOTE ON THE PLAN HAS A REFERENCE TO THE ACTUAL ELEVATION, BUT THE NOTE IS INCOMPLETE. PLEASE VERIFY. 3. SHEET S2.3 (ROOF PLAN NOTES); STRUCTURAL CALCULATIONS (DESIGN LOAD SCHEDULE): THE PLAN NOTE (#7) INDICATES A 6" CONCRETE PAD ON THE ROOF AT RTU LOCATIONS, WHILE THAT LOAD DOES NOT APPEAR IN THE DESIGN LOAD SCHEDULE. PLEASE VERIFY. 4. SHEET S2.3 (ROOF FRAMING PLAN); SHEET M2.1: PLEASE INDICATE THE ESTIMATED RTU LOCATIONS ON THIS PLAN (REFERENCE PRELIMINARY SHEET M2.1). 5. SHEET S3.0; DETAILS AT SUMP: PLEASE INDICATE ON THE PLAN WHERE THE SUMP PIT IS LOCATED IN THE ELEVATOR PIT. 6. SHEET S3.0; DETAIL AT SITE RETAINING WALL: WERE STRUCTURAL CALCULATIONS SUBMITTED FOR THIS WALL DESIGN? IS IT PART OF THIS PERMIT? PLEASE VERIFY. 7. SHEETS S3.0, S4.0, AND S4.1: PLEASE NUMBER THE DETAILS AND INDICATE ON THE APPROPRIATE PLAN WHERE THOSE DETAILS ARE CUT. 8. GENERAL: ALL STRUCTURAL DRAWINGS FOR THIS SUBMITTAL SHALL HAVE THE SEAL OF THE ENGINEER OF RECORD DATED. IN ADDITION, THE EXPIRATION DATE OF THE LICENSE MUST BE INDICATED BELOW THAT SEAL. 9. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 12/21/2015 | ERIC NEWCOMB | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 12/21/2015 | ERIC NEWCOMB | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 12/21/2015 | ENEWCOM1 | WATER | REVIEW | Passed | |
| 12/21/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/21/2015 | ERIC NEWCOMB | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 12/30/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Reqs Change | Approval of DP15-0204 is required for building approval by the zoning review section. |
| 12/30/2015 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Reqs Change | Needs DP15-0204 approval first. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/12/2016 | AROMERO4 | OUT TO CUSTOMER | Completed |