Permit Number: T15CM08146
Parcel: 130020270

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM08146
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/06/2016 ARUIZ1 NPPO REVIEW Needs Review
09/06/2016 ARUIZ1 BUILDING-RESIDENTIAL REVIEW Needs Review
11/20/2015 DAVID RIVERA ZONING REVIEW Denied P&DS TRANSMITTAL


FROM: David Rivera, Principal Planner

PROJECT:
T15CM08146
1610 S. Country Club
Detached Garage on Single Family R-1 Zone property



TRANSMITTAL: August 4, 2015


COMMENTS: the following comments are relative to an application for a Board of Adjustment Variance UDC Section 3.10.1 request for Building Height and Setbacks and detached accessory square footage relative to the principal structure.




This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

6.6.3. SPECIFICALLY WITHIN RESIDENTIAL ZONES

The buildings used for an accessory use within a residential zone shall comply with the following:

C. Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure; and,

D. The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa are exempt from this requirement.

01. Comment: The owner proposes to construct a detached three car garage in the rear yard three feet from the south and east property lines. The wall height is 18 feet from design grade. The allowed building setbacks are the greatest of 6 feet or two thirds the height of the building wall facing the property line. The required building setbacks are 12 feet from the south and east property lines, the owner proposes 3 feet along the south and east property boundary.

02. Comment: UDC Section 6.6.3.C - Detached accessory structures within residential zones shall not exceed 12 feet in height, the owner proposes 16 feet 6 inches at the mid point of the of the roof.

03. Comment: UDC Section 6.6.3.D - Detached accessory structures within residential zones shall not exceed 50% of the GFA of the principal structure. The Principal structure is 955 square feet. The owner proposes a detached accessory structure of 1,768 square feet. The detached accessory structure is 185% the size of the principal structure.
11/20/2015 PAUL BAUGHMAN ENGINEERING REVIEW Approved