Permit Number: T15CM07778
Parcel: 10511061R

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM07778
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2015 MICHAEL ST. PAUL ZONING REVIEW Approved
11/06/2015 PAUL BAUGHMAN ENGINEERING REVIEW Approved
11/09/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03.
2. Provide tempered water for the restroom lavatory using an approved device conforming to ASSE 1070. Reference: Section 607.1.2, IPC 2012.
3. Provide an approved vacuum relief valve for the scheduled bottom-fed water heater which is located above the fixture outlets. Reference: Section 504.2, IPC 2012.
11/09/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
11/09/2015 KEN BROUILLETTE FIRE REVIEW Approved
11/09/2015 ROBERT SHERRY WATER REVIEW Completed
11/12/2015 CLAYTON TREVILLYAN BUILDING-COMMERCIAL REVIEW Completed
11/12/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
11/12/2015 CTREVIL1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed