Permit Number: T15CM06998
Parcel: 12212011A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM06998
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2015 MICHAEL ST. PAUL ZONING REVIEW Approved
10/09/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Replot drawings for legibility.
10/09/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
10/09/2015 JASON GREEN ENGINEERING REVIEW Approved
10/09/2015 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET A2.0; DETAIL 5: PER THE IBC 1607.14, INTERIOR PARTITIONS MUST HAVE ADEQUATE STRENGTH TO RESIST A 5 PSF HORIZONTAL LOAD. PLEASE PROVIDE BRACING ON THIS DETAIL. INCLUDE BRACING SIZE, SPACING, AND CONNECTION (SIZE AND QUANTITY) TO THE STRUCTURE ABOVE AND TO THE TOP OF THE PARTITION.
2. GENERAL: IS THERE DEMOLITION INVOLVED IN THIS PROJECT? PLEASE PROVIDE A DEMOLITION PLAN AS REQUIRED.
3. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
10/09/2015 ROBERT SHERRY WATER REVIEW Completed
10/09/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Replot drawings for legibility.
10/09/2015 MARTIN BROWN FIRE REVIEW Approved
10/09/2015 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed