Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T15CM06852
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/05/2015 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 10/16/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 10/16/2015 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 10/16/2015 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 10/16/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Demonstrate energy code compliance for the building envelope using calculations based on the current code. Reference: Sections C101.3, C101.5, and C103.2, International Energy Conservation Code 2012. 2. Specify the required NFRC-certified U-factors and Solar Heat Gain Coefficients (SHGC) for the storefront and windows on the architectural drawings (e.g. see the Door Note on sheet A4.0). Reference: Sections C103.2 and C303.1.3, IECC 2012. |
| 10/21/2015 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/27/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 10/28/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET T1.0; CODE REVIEW CHECKLIST: PLEASE SHOW THE CALCULATIONS ON THIS SHEET FOR THE AREA INCREASE DUE TO THE BUILDING FRONTAGE. INCLUDE THE IBC EQUATION 5-2 FOR THIS CALCULATION. 2. SHEETS A1.1, A1.2, AND A1.3: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE NOTES. 3. SHEET A2.0; FLOOR PLAN: WHAT DOES THE ASTERISK IN THE EXTERIOR DOORS INDICATE? PLEASE PROVIDE A REFERENCE ON THE PLAN. 4. SHEET A2.0; FLOOR PLAN: PLEASE VERIFY DOORS 1 AND 5 IN THE OPEN SPACE ARE EQUIPPED WITH PANIC HARDWARE AS REQUIRED BY THE IBC SECTION 1008.1.10. 5. SHEET A2.0; FLOOR PLAN: PER THE IBC SECTION 1109.11, ACCESSIBLE SEATING SPACES ARE REQUIRED IN THE OPEN SPACE. PLEASE INDICATE ON THE DRAWINGS THE NUMBER OF ACCESSIBLE SPACES REQUIRED, AND INDICATE ON THE FLOOR PLAN THE LOCATION OF THOSE SPACES. 6. SHEET A2.0; FLOOR PLAN: PLEASE INDICATE IN NOTE 5 (WALL SCHEDULE) THE UL NUMBER FOR THE ONE HOUR FIRE RATED WALL BETWEEN THE GARAGE AND THE HEALTH SERVICES. 7. SHEET S0.1; GENERAL STRUCTURAL NOTES (FOUNDATIONS): PLEASE PROVIDE THE SOIL REPORT FOR REVIEW. 8. SHEET S4.0 (DETAILS 101 AND 103); STRUCTURAL CALCULATIONS (SHEET 15): THE CALCULATIONS INDICATE THE EXTERIOR FOUNDATION SHALL BE A 12" WIDE X 18" THICK CONTINUOUS TURNDOWN. THE DETAILS INDICATE A 6" FOUNDATION DEPTH BELOW FINISH GRADE, AND THE GENERAL STRUCTURAL NOTES SUPPORT THE 6" DEPTH. PLEASE COORDINATE THE DEPTH OF THE FOUNDATION BETWEEN THE CALCULATIONS AND THE DRAWINGS. 9. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 10/29/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/03/2015 | KROBLES1 | OUT TO CUSTOMER | Completed |