Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T15CM06750
Parcel: 133132120

Address:
7620 E HELEN ST

Review Status: Active

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T15CM06750
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/22/2015 ANY ZONING REVIEW Active
10/22/2015 ANY ENGINEERING REVIEW Active
10/23/2015 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T15CM06750

PLAN REVIEW COMMENTS
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code, 2012 International Fire Code, 2011 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

GENERAL NOTES:

" Provide only one copy of the Label Set sheet. The second unused copy slows the review process.
DIAGRAMS / CALCULATIONS

1. Show the sum of the main and backfeed breakers not exceeding 120% of the busbar (and conductor) rating, NEC 690.64 & 705.12 (D). The 150A distribution panel extended bus conductor (4) requires a rating for receiving electrical power from two sources. Upgrade conductor (4) with a 141.7A rating when placed between source breakers of 150A & 20A. (141.7A conductor x 120% equal or grater than 150A + 20A) or move the backfeed breaker to the service panel.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review