Permit Number: T15CM06372
Parcel: 131120980

Address:
6121 E 30TH ST

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM06372
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2015 ANY ENGINEERING REVIEW Active
09/14/2015 ANY BUILDING-RESIDENTIAL REVIEW Active
09/18/2015 MICHAEL ST. PAUL ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T15CM06372
6121 East 30th Street
Addition to SFR


TRANSMITTAL: September 18, 2015


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The height of the structure's wall facing the west property line is twenty-four (24) feet, six (6) inches. The required setback is sixteen (16) feet, four (4) inches. The proposed setback to the west property line is one (1) foot.
09/18/2015 MICHAEL ST. PAUL NPPO REVIEW Passed