Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2015 MICHAEL ST. PAUL ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T15CM05940
2524 East Lester Street
Duplex (2 story lofts)


TRANSMITTAL: September 18, 2015


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The height of the structure's walls facing both the east and west property lines is twenty-one (21) feet, eight (8) inches. The required setbacks are fourteen (14) feet, six (6) inches to both property lines. The proposed setbacks are nine (9) feet to both the east and west property lines.
09/18/2015 MICHAEL ST. PAUL NPPO REVIEW Passed
12/29/2015 EGALLET1 ENGINEERING REVIEW Needs Review
12/29/2015 EGALLET1 BUILDING-RESIDENTIAL REVIEW Needs Review