Review Details: RESUBMITTAL - TI ALL
Permit Number - T15CM05730
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/04/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The submitted calculations correctly indicate that eight 48-inch wide scuppers will be required for the main roof but the architect shows eight 16-inch wide scuppers draining the main roof east of column line 5 and no drainage for the main roof from column line 5 through column line 7. No drainage is shown for the pharmacy canopy. Coordinate the roof drainage with the architect. The minimum dimension for a scupper is 4" so a 0.90" scupper width is not allowed (Section 1108.3, IPC 2012). [Second comment: A scupper is a weir, not horizontal pipe and its cross-sectional area does not determine its capacity. Consult with the structural engineer to determine the maximum rainwater depth that the roof can accommodate. Reference: Sections 1611.1 and 1611.3, IBC 2012.] [Initial comment: Provide roof drainage and hydraulic scupper size calculations based on the 100-year hourly rainfall rate for Tucson, 3" per hour. Reference: Sections 1106.1, 1106.4, and 1108.3, IPC 2012.] 2. The minimum dimension for a scupper is 4" so a 0.90" scupper width is not allowed (Section 1108.3, IPC 2012). [Second comment: A scupper is a weir, not horizontal pipe and its cross-sectional area does not determine its capacity.] [Initial comment: Provide calculations to show that the overflow pipe (note 07-111, A3.1.1) for the canopy has the same capacity as the roof drain provided for the canopy. Reference: Sections 1101, 1106 and 1108, IPC 2012, and Sections 1611.1 and 1611.3, IBC 2012.] |
01/04/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
12/18/2015 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approved | |
12/22/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
12/28/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved |