Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T15CM05594
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2015 | DAVID RIVERA | ZONING | REVIEW | Passed | |
| 08/12/2015 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 08/12/2015 | JGREEN2 | NPPO | REVIEW | Passed | |
| 08/12/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 8-12-15 Activity: T15CM05594 Address: 808 S. Jerrie Av Applicant: Inai Maldonado This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. 1. Specify the location of all utility lines and service meters, R106.1.1. Include the location of the proposed building drain and point of connection to the existing sewer line. 2. Provide a porch beam sized to support the proposed roof area, R801.2. A 4x6 beam spanning 10 feet is not adequate to support 6 feet of tributary roof area. 3. Please justify the rafter connection to the existing building. Attaching new rafters to an existing fascia will impose additional loads to the tails of the existing rafters. Positive connection is required to the existing building that will sufficiently transfer the proposed load, R801.2. 4. The post base hardware indicated is not intended for use with the post size specified, please revise. 5. Specify the size of the proposed water meter, the lowest available water pressure and the diameter of the water supply line from the meter to the service entrance, P2903.7. The Tucson Water policy adopted 7/13/12 limits the maximum demand for a 5/8" water meter to 15 GPM; Reference Tables P2903.6 and P2903.6 (1), IRC 2012. 6. Please indicate the method of return air from the bathroom if a new supply duct will be installed, M1602.1. Undercutting the separating door must be indicated if this is the proposed method. 7. Tile wall surfaces surrounding tub/shower areas require cement, fiber-cement, or glass-mat board backing, R307.2, R702.4.2. Please notate accordingly. If you have any questions please contact: Clayton Trevillyan, CBO 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |