Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T15CM05445
Parcel: 12701003K

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM05445
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2015 KEN BROUILLETTE FIRE REVIEW Approved
09/28/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide automatic faucets for the lavatories, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucets will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03.
2. Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012.
3. Water supply connections to beverage dispensers (e.g. coffee makers) shall be protected with backflow preventers conforming to ASSE 1022. Reference: Sections 608.16.1 and 608.16.10, IPC 2012.
4. Provide an air gap discharge for the potable clear water waste from the ice machine and the intermediate atmospheric vents of the ASSE 1022-listed backflow preventers. Reference: Section 802.1.3, IPC 2012.
5. Show that the floor drain used as an indirect receptor for condensate and the water heater temperature and pressure relief are capable of accepting the maximum discharge and are designed to prevent splashing or flooding. Reference: Section 802.3.1, IPC 2012.
6. Verify that all of the vents rise vertically to at least 6" above the flood rims of the fixtures they protect prior to running horizontally (e.g. the showers and floor drain). Reference: Section 905.4, IPC 2012.
7. If the specified water heater is not supplied with integral heat traps, provide heat traps on the supply and discharge piping. Reference: Section C404.4, IECC 2012.
8. If the specified water heater is not supplied with integral heat traps, provide 0.5" of insulation with a maximum conductivity of 0.27 BTU per inch/h F on the first 8 feet of supply and discharge piping. Reference: Section C404.5, IECC 2012.
09/28/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Show the size, routing, and termination of the condensate drains from CRU-1 and CRU-2. Reference: Section 307.2.1, IMC 2012 as amended by the City of Tucson.
2. The occupant load used to calculate the required ventilation is not necessarily the same as the occupant load used for calculating exiting requirements or the furniture layout. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3, IMC 2012 or an approved engineering analysis of the specific occupancy type. Reference: Section 403.3, IMC 2012.
09/28/2015 ROBERT SHERRY WATER REVIEW Completed
09/29/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please provide full compliance with the IECC for interior lighting.