Permit Number: T15CM05182
Parcel: 123071190

Address:
1202 N NORRIS AV

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM05182
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2015 ANY NPPO REVIEW Active
07/28/2015 ANY ENGINEERING REVIEW Active
07/28/2015 ANY BUILDING-RESIDENTIAL REVIEW Active
07/29/2015 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera, Principal Planner
TRANSMITTAL: September 17, 2015
ADDRESS: 1202 N. Norris Avenue
ACTIVITY NUMBER: T15CM05182 (Second Review)
PROJECT: Interior remodel on Main dwelling and a second story addition

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).
This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.
The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).
1. Comment: Owner proposes to construct an addition that includes a second story.
2. The required building setback based on a 13'-2" wall height for the first story is 8'-8" and the proposed building setback is 5'-0" from the east property line.

The second floor has been stepped back to provide a 10' building setback from the east property line. The required building setback for the second story, based on a 23'-4" wall height, is 15'-6" and the proposed building setback is 10'-0" from the east property line.

3. The required building setback based on a 13'-2" wall height for the first story is 8'-8" and the proposed building setback is 5'-0" from the north property line.

The second floor has been stepped back to provide a 10' building setback from the north property line. The required building setback for the second story, based on an 18'-1" wall height, is 12'-0" and the proposed building setback is 10'-0" from the north property line.

*****************************************************************


P&DS TRANSMITTAL


FROM: David Rivera, Principal Planner
TRANSMITTAL: July 29, 2015
ADDRESS: 1202 N. Norris Avenue
ACTIVITY NUMBER: T15CM05182
PROJECT: Interior remodel on Main dwelling and a second story addition

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

1. Comment: Owner proposes to construct an addition that includes a second story. The proposed setback is 5'-0" from the east property line. The required building setback based on the 18'-6" wall height along the east property line is 12'-4".

2. Comment: Owner proposes to construct an addition that includes a second story. The proposed setback is 5'-0" from the north property line. The required building setback based on the 25'-6" wall height along the north property line is 17'-0".

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b).

3. Comment: Owner proposes to construct an addition that includes a second story. The required building setback along the side street is 10'-0", the owner proposes 7'-9".