Permit Number: T15CM04708
Parcel: 125041560

Address:
2350 E 1ST ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM04708
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/10/2015 MICHAEL ST. PAUL ZONING REVIEW Approved P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T15CM04708
2350 East First Street
Detached garage with sleeping quarters


TRANSMITTAL: July 10, 2015


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The height for the proposed detached structure is thirteen (13) feet, nine (9) inches facing the west property line. The required setback is nine (9) feet, two (2) inches. The proposed setback is three (3) feet, four (4) inches to the west property line.
07/10/2015 MICHAEL ST. PAUL NPPO REVIEW Passed
11/18/2015 LOREN MAKUS ENGINEERING REVIEW Approved
11/18/2015 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review