Permit Number: T15CM04193
Parcel: 123060100

Address:
1951 E LEE ST

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM04193
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
06/19/2015 STEVE SHIELDS ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Steve Shields, Lead Planner

PROJECT:
T15CM04193
1951 E. Lee Stret
Master Bedroom Addition and 7'-4" site wall


TRANSMITTAL: June 19, 2015


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Based on a 14'-4" building wall the required perimeter yard setback to the west property is 9'-6", proposed perimeter yard setback is 8'-9".

The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall (UDC Section 6.6.2.I.2). Proposed wall height 7'-4".
06/19/2015 ANY ENGINEERING REVIEW Active
06/19/2015 SSHIELD1 NPPO REVIEW Passed
06/19/2015 ANY BUILDING-RESIDENTIAL REVIEW Active