Permit Number: T15CM03580
Parcel: 117120200

Address:
35 N 6TH AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T15CM03580
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/03/2015 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approv-Cond CONDITIONAL APPROVAL: ANY ADDITIONS OR ALTERATIONS INCREASING THE HEIGHT OF THE EXISTING ADJACENT BUILDING TO THE NORTH COULD REQUIRE THE OPENINGS ON THE NORTH WALL OF THIS BUILDING TO BE INFILLED WITH THE SAME MATERIAL AS THE WALL CONSTRUCTION (ONE HOUR FIRE RATING). WITH THE INFILLED WINDOWS, A NEW ANALYSIS BY A LICENSED ARCHITECT FOR THE NATURAL LIGHTING WILL BE REQUIRED PER THE IBC SECTION 1205, AND A NEW ANALYSIS BY A LICENSED ARCHITECT FOR THE NATURAL VENTILATION WILL BE REQUIRED PER THE IBC SECTION 1203.4.