Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T15CM03330
Parcel: 11460019C

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM03330
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/19/2015 STEVE SHIELDS ZONING REVIEW Approved
05/19/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
05/19/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please provide electrical for new restroom exhaust fan. Panel schedules do not show existing water heater or exhaust fans.
05/19/2015 ROBERT SHERRY WATER REVIEW Completed
05/19/2015 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET G1; BUILDING CODE INFORMATION: THE BUILDING CODE INFORMATION INDICATES THE OCCUPANCY TYPE AS BUSINESS (B). UNDER THE 'TOILET FACILITY NOTES', IT IS INDICATED THAT THE SPACE IS MERCANTILE (M). PLEASE CLARIFY.
2. SHEET G1; BUILDING CODE INFORMATION: THE OCCUPANCY LOAD IS BASED ON A BUSINESS USE (100 SF PER PERSON GROSS), BUT IT IS INDICATED ONLY ONE WATER CLOSET AND LAVATORY ARE REQUIRED. FOR A BUSINESS USE, 16 OCCUPANTS REQUIRE TWO SEPARATE FACILITIES PER THE IBC SECTION 2902.2 EXCEPTION 2. PLEASE VERIFY.
3. SHEET G1; BUILDING CODE INFORMATION: PLEASE ADDRESS THE PLUMBING REQUIREMENT ON THE DRAWINGS FOR DRINKING FOUNTAINS.
4. SHEET A1; DEMOLITION PLAN: KEYNOTES ARE LISTED BELOW THE DEMOLITION PLAN, BUT NO KEYNOTES ARE INDICATED ON ANY OF THE PLANS. PLEASE VERIFY.
5. GENERAL: PLEASE CLARIFY THE OCCUPANCY USE. IF IT IS BUSINESS (EYE EXAMS, CONSULTATIONS, ETC.), CALCULATE THE OCCUPANCY LOAD AND PLUMBING FIXTURE REQUIREMENTS (IBC TABLE 2902.1) BASED ON THE B USE. IF IT IS RETAIL (EYEWEAR SALES), CALCULATE THE OCCUPANCY LOAD AND PLUMBING FIXTURE REQUIREMENTS BASED ON THE M USE.
6. GENERAL: PLEASE PROVIDE A DETAIL ON THE DRAWINGS INDICATING THE BRACING AT THE TOP OF NEW INTERIOR PARTITIONS IN ORDER TO RESIST HORIZONTAL LOADS INDICATED IN THE IBC SECTION 1607.14. INCLUDE THE BRACING SIZE AND SPACING, CONNECTION (SIZE AND QUANTITY) OF THE BRACING TO THE TOP OF THE WALL, AND CONNECTION (SIZE AND QUANTITY) OF THE BRACING TO THE EXISTING STRUCTURE ABOVE.
7. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
05/19/2015 RSHERRY1 WWM REVIEW Passed No water meter size change.
05/19/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Verify that the developed pipe length for the hot water service to P-1 is 50-feet or less. Reference: Section 607.2, IPC 2012.
2. Provide the size of the new gas pipe running from the new gas meter to the connection with the existing gas pipe on the roof (keynote #11).
3. Provide the developed length of the gas pipe serving AC-1 from the new gas meter.
05/19/2015 LOREN MAKUS ENGINEERING REVIEW Approved
05/19/2015 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
05/20/2015 MARTIN BROWN FIRE REVIEW Approved