Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T15CM03201
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/16/2015 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T15CM03201 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. Update the living area to 784 SF and the porch to 140 SF on sheet #2. Also, show 630 SF for the Garage on sheet #2G. 2. A dwelling unit providing complete independent living facilities requires compliance with design ordinances for handicap provisions, solar water, photo-voltaic and gray water preparations. Design Ordinances adopted by the City of Tucson. 3. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. 4. All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation City of Tucson Ordinance #10549 with one of the following provisions: ½"control conduit and two ¾" copper piping for water with rooftop termination; straight 3" capped sleeve; or an accessible attic (clear path 30" wide x 30" high) over the water heater. Show appropriate notation. 5. All SFR and Duplex plans submitted after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 with the following provisions: 1. A 4 square feet area for (meter, disconnect & inverter) equipment adjacent to the electrical service panel or near the proposed collector panel space. 2. The best roof space available for accommodating PV solar collector panels with capacity for collector dead loading (typically 4 lbs/SF). 3. A minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation (Show as a continuous load of 15.8 A). 4. An Electrical Panel Schedule with a 240 volt circuit breaker space labeled "reserved for Photo Voltaic". 6. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. One story dwellings must have a gray drain line discharge. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade, or a bathing fixture drain looped 3' beyond an exterior wall below grade before connection to the building drain. See details at http://pdsd.tucsonaz.gov/files/pdsd/codes-ordinances/Grey_Water_Options_FINAL_.pdf FLOOR PLANS: 1. Show a maximum ½" floor elevation change at a notated accessible route entrance on the floor plan, R106.1.1. 2. Exterior walls with a fire separation distance less than 3-foot must have not less than one-hour fire-resistive construction. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 720.1(2), Items 15-1.1 to 16-1.3. Show compliance for the dwelling and garage with the rating identification. 3. Projections (porch roof) may not extend to a point closer than 2 feet from the property line. Provide notation for compliance with R302.1 (City of Tucson Amended) by removing the roof overhang, or show a fire rated wall between the structure and property line R301.1. STRUCTURAL PLANS: 1. Provide a complete prescriptive braced wall design, R602.10, with a minimum of 3/8" OSB sheathing (at sheet #4 & 4G), or provide an engineering report identifying the required installation method, or provide a structural design by a registered engineer in the state of Arizona, Arizona Statute 32-144.4. 2. Provide a complete braced wall design with garage opening narrow panels including fastening details using a prescriptive method at Figure R602.10.6.2, R602.10.6.3 or R602.10.6.4, or provide an engineer's calculation, design and seal for shear wall placement. 3. Walls (1 hour rated) inside the 3-foot fire separation distance may not include window openings, R302.1. Remove the Garage window near the property line. ELEVATIONS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. 2. If the unvented roof assembly method will be utilized then specify a layer of air-impermeable rigid insulation material (fiberglass does not qualify) tight to the roof sheathing with a minimum R-5 value, R806.5. This condensation control provision is necessary for code compliance and may be layered with batt insulation for achieving the total required roof R value. 3. If a vented roof assembly method will be utilized then provide an attic space ventilation calculation and specify size and location of all vents needed to comply with R806.2. Provide appropriate upper and lower space vents if applying the reduced area calculation per exception requirements. SECTIONS - DETAILS: 1. Show an exterior post with a metal pedestal base with 1" space above concrete at detail #9/3, R319.1.4 exception 1. The CB66 does not include the standoff base. PLUMBING PLANS: 1. Show hot water pipe with minimum R-3 insulation, N1103.4.2. 2. Provide a water hammer arrester for quick-closing valves serving the clothes washer, P2903.5. 3. Provide branch drain pipes in accordance with Table P3005.4.1 and vent (VTR) P3105.1 for the clothes washer. 4. Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). Clarify the 60' long run notation on sheet #7. The gas meter appears as 100 feet from the dwelling on the site plan, if so upsize the 1" pipes to 1-1/4" and ¾" to kitchen area to 1". 5. A single story dwelling requires either a clothes washer with one standpipe plumbed through an exterior wall, or one gray water fixture preparation with under floor gray drainage plumbing, Ordinance #11089. Provide a bathing fixture drain looped 3' beyond an exterior wall below grade before connection to the building drain. See details at http://pdsd.tucsonaz.gov/files/pdsd/codes-ordinances/Grey_Water_Options_FINAL_.pdf ELECTRICAL PLANS: 1. Add a double breaker space for future Photo Voltaic on the panel schedule. 2. Show locations of each smoke alarm, R314. Notate that all smoke alarms must be interconnected with a power source from the building wiring, and be equipped with battery backup. 3. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm on each side of the bedroom doors in the immediate vicinity. 4. Show or notate the requirement for a carbon monoxide detector outside of bedroom doors, when the dwelling includes an attached garage or gas appliance, R315. 5. Provide an electrical riser diagram, E3403. Notate the grounding and bonding method, E3607. Metallic gas lines must be bonded and not be used as the primary grounding method, E3608. 6. Provide a readily accessible Service Disconnect for each dwelling unit, E3601.6.2 that disconnects all service with not more than six switches, E3601.7. Two dwellings may not use a common branch circuit load center. 7. Show the location of the panel on the Electrical Plan, E3601.6.2 & E3705.8. 8. Show the sub-panel feeder size and over-current protection (breaker size), E3705.5, or a second TEP service. 9. Show the Bathroom receptacle on a separate 20 AMP circuit (dedicated) with outlets at no other location, E3703.4. 10. Show a GFCI receptacle outlet on the same level within 25' of exterior HVAC equipment, E3901.12. 11. Show all garage receptacle outlets with GFCI protection, E3902.2. Include the ceiling receptacle on circuit #40. 12. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. OUTDOOR LIGHTING CODE 1. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property along with the three proposed fixtures in the calculation. All fixtures are assumed to be unshielded (non-FCO style) unless shown as full cut-off FCO style. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and walls R=13. Update the "U" factors of the windows and doors on sheet #2 and 2G. Also, show the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1. 2. Update the roof insulation value shown on Section A, sheet #3, N1102.1. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/17/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |