Permit Number: T15CM02735
Parcel: 141186040

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T15CM02735
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/19/2015 DAVID RIVERA ZONING REVIEW Approved
06/29/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following comment;
As per the last plan review, it was requested to show full compliance with the Tucson Outdoor Lighting Code. The exterior lighting color temperature output is shown at 40K for the specified luminaires. This is in violation of the Outdoor lighting Code per sec. 402 1. Not to exceed 35K.
07/09/2015 CLAYTON TREVILLYAN BUILDING-COMMERCIAL REVIEW Completed
07/13/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Comment not resolved; the data for the windows does not indicate that the SHGC was determined using NFRC Standard 200 and no data was provided for the U-values for the doors. [Initial comment: Revise the energy code analysis for the building envelope, coordinating the building components used in the analysis with those shown on the drawing (i.e. use the wall construction shown on the drawings or change the drawings to match the COMcheck components) and provide the supporting documentation for the U-factors used in COMcheck. Reference: Section C303.1, IECC 2012, as amended by the City of Tucson.]
2. See the comment above. [Initial comment: Provide NFRC fenestration product ratings for the U-factor and the SHGC values on COMcheck or use the appropriate default U-factor and SHGC values from Tables C303.1.3 (1), C303.1.3 (2) and C303.1.3.(3), IECC 2012. Reference: Section C303.1.3, IECC 2012.
07/13/2015 ROBERT SHERRY WATER REVIEW Completed
07/13/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Sheet M-2 has been revised to show that the plumbing design has been done per the 2006 Uniform Plumbing Code. The City of Tucson adopted the 2012 International Code in 2013. Revise the code references to show the correct codes. [Initial comment: The plumbing notes on sheet M-2 indicate that the plumbing design has been done per the 2012 International Plumbing Code. Revise the references to the 2006 UPC on the drawing to show the applicable sections of the 2012 IPC. Reference: Section 101.4, IBC 2012, as amended by the City of Tucson.]