Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T15CM02073
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 03/31/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 03/31/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 03/31/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 04/01/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 04/01/2015 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please provide IECC code compliance for lighting. |
| 04/01/2015 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/01/2015 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 04/01/2015 | AROMERO4 | WWM | REVIEW | Completed | |
| 04/01/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Section 301.2, IPC 2012. 2. Provide the specifications and listing information for the proposed water heater. Reference: Sections 303.2 and 501.5, IPC 2012 and Section 107.2.1, IBC 2012. 3. Provide a detail of the water heater installation, including the excess pressure relief, expansion tank, vacuum relief or other anti-siphon device, safety pan, and valves. Reference: Sections 503, 504, 606.1, and 607.3, IPC 2012. 4. Provide a direct connection for the hand sink. Reference: Sections 301.3 and 802.1, IPC 2012. 5. Hand sinks in the kitchen are allowed to connect to the sanitary waste system instead of the grease waste system only if each sink has a sign posted above it stating, "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED." Reference: Section 1003.3, IPC 2012, as amended by the City of Tucson. 6. The drain for the new mop sink is noted as being connected to the existing grease waste line but the plumbing plan shows the drain from the mop sink bypassing the grease interceptor. 7. The new water heater is noted as being gas-fired; provide a natural gas piping design, including the piping layout on a floor plan and a natural gas schematic showing the sizes, loads and developed lengths of the piping. Reference: Section 107.2.1, IBC 2012. 8. Specify the type of venting systems and the venting materials to be used for the proposed appliances. Reference: Section 503.1, IFGC 2012. 9. Verify that the new flue does not pass through an HVAC plenum. Reference: Section 601.4, IMC 2012. |