Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T15CM01605
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/02/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 4-06-15 Activity: T15CM01605 Address: 2726 E. Manchester Applicant: Thomas Higbie This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code and local amendments. In order to facilitate a shorter back check time, we request that you provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Specify the location of all utility lines and service meters on the site plan including underground feeders to detached buildings, R106.1.1. FOUNDATION PLAN: 2. All exterior framed walls require continuous concrete footings min. 12"wide x 12" below grade with treated sill plates and anchor bolts per R403.1 & R403.1.6. Ref. sheet A1.2. STRUCTURAL / FRAMING PLAN: 3. Specify sizes of all headers and beams, R801.2. 4. Provide a complete braced wall line layout showing the location of braced wall panels within 10 feet of each end of each braced wall line and shall be no more than 20 feet apart, R403.1.6, R602.10.2.2. ELEVATIONS: 5. Specify roof slope and roof covering type for detached storage shed, R905. PLUMBING PLAN: 6. The City of Tucson has adopted the 2012 International family of codes. As of 1/01/2013 all code references should refer to the currently adopted code or appeal must be made to the Building Official for use of the 2006 IRC or amendments adopted by Pima County. 7. Provide a water fixture unit schedule for all plumbing fixtures supplied by the water meter (including existing) P2903.6. 8. Specify the size of the proposed water meter and the diameter of the water supply line from the meter to the service entrance, P2903.7. The Tucson Water policy adopted 7/13/12 limits the maximum demand for a 5/8" water meter to 15 GPM; Reference Tables P2903.6 and P2903.6 (1), IRC 2012. MECHANICAL PLAN: 9. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. If you have any questions please contact: Clayton Trevillyan, CBO 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/06/2015 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |