Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T15CM01505
Parcel: 122124200

Address:
1619 N SWAN RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM01505
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2015 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
03/05/2015 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/06/2015 LOREN MAKUS ENGINEERING REVIEW Approved
03/06/2015 MICHAEL ST. PAUL ZONING REVIEW Approved
03/09/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Provide energy code compliance calculations for the building envelope; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C101.4.5, C103.2, and C401.2, International Energy Conservation Code 2012.
2. Provide NFRC fenestration product ratings for the U-factor and the SHGC values on COMcheck or use the appropriate default U-factor and SHGC values from Tables C303.1.3 (1), C303.1.3 (2) and C303.1.3.(3), IECC 2012. Reference: Section C303.1.3, IECC 2012.
03/09/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
03/09/2015 ROBERT SHERRY WATER REVIEW Completed
03/09/2015 KEN BROUILLETTE FIRE REVIEW Approved
03/09/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/13/2015 AROMERO4 WWM REVIEW Completed