Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T15CM01097
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/19/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
02/19/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
02/19/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the specified faucet for the two handwashing sinks in the lavatories is equipped with a mixing valve that complies with ASSE Standard 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012. 2. Provide separate indirect waste pipes for each compartment of the 3-compartment sink to protect against cross-contamination or fouling. Reference: Sections 801.2 and 802.1.8, IPC 2012. 3. Clarify the reason for using an indirect waste connection for the soiled dish table sink. Reference: Section 802.1, IPC 2012. |
02/19/2015 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Provide the size of the existing water meter and provide the total demand served by the water meter. |
02/19/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
02/20/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET G001; PROJECT RESPONSIBILITY MATRIX: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE. 2. SHEET G001; CODE ANALYSIS: PLEASE INDICATE ON THE DRAWING THAT THIS BUILDING HAS AUTOMATIC SPRINKLERS. 3. SHEET G003; LIFE SAFETY PLAN: THE PLAN INDICATES THE DIAGONAL DISTANCE OF THE AREA SERVED IS 119'-5". ANOTHER NOTE INDICATES THE REQUIRED SEPARATION BETWEEN EXITS IS 1/3 OF THE AREA SERVED = 35'-8". SHOULD THIS NUMBER BE 39'-8"? PLEASE VERIFY. 4. SHEETS D100 AND A100; ELEVATIONS: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE. 5. SHEET A600; INTERIOR FINISH SCHEDULE: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE. 6. SHEET A702; DETAIL 5: PLEASE PROVIDE THE BAR HEIGHT ON THE DETAIL. 7. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
02/20/2015 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
02/20/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
03/04/2015 | AROMERO4 | WWM | REVIEW | Completed | |
03/04/2015 | AROMERO4 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review |