Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T15CM01040
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2015 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T15CM01040 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. FOUNDATION PLANS: 1. Dimension the footing width, R403.1. Minimum footing width required for one story construction is 12" with a minimum ½" diameter with (anchor bolt length for assuring) 7" embedment into concrete or masonry. Show these dimensions on detail #1/8. 2. Show exterior sheathing and wall framing with a 6" clearance above the ground (R317.1 item 5). Show this dimension on detail #1/8. PLUMBING PLANS: 1. A 3-way valve is not approved for waste piping, P2609.2. Show a gray water system consistent with P3009, or plumb the gray drain directly into the building waste without a valve. MECHANICAL PLANS: 1. Show dryer vent size and location for venting to exterior, M1501. ELECTRICAL PLANS: 1. Show each circuit on the panel schedule with protection rating, E3702.2. Include C17. 2. Show all receptacle outlets located within 6' of a sink with ground fault circuit interrupting protection, E3902. Include the wall mounted receptacle on C6 across from the storage room sink and the countertop receptacles on C17. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/16/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |