Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T15CM00876
Parcel: 136213200

Address:
7160 E 42ND ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM00876
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2015 DAVID RIVERA ZONING REVIEW Denied P&DS TRANSMITTAL


FROM: David Rivera - Principal Planner
TRANSMITTAL: March 13, 2013
PROJECT NUMBER: T14CM00876
ADDRESS: 7160 E 42nd Street
PROPOSED PROJECT: ATTACHED CARPORT



COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).


COMMENT: The applicant is applying for a building permit for an attached unpermitted carport structure. The structure was constructed two (2) feet eight (8) inches foot from the street property line. A minimum of 20 feet for the building is required and 18 feet for the driveway. A DDO for setbacks is required.
03/13/2015 DRIVERA1 ENGINEERING REVIEW Needs Review
03/13/2015 DAVID RIVERA NPPO REVIEW Passed
03/13/2015 DRIVERA1 BUILDING-RESIDENTIAL REVIEW Needs Review