Permit Number: T15CM00867
Parcel: 128111060

Address:
5003 E TIMROD ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM00867
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/10/2015 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera, Principal Planner

PROJECT: T15CM00867
5003 E Timrod Street
New Attached Carport and Work/Garage

TRANSMITTAL: February 10, 2015


COMMENTS: The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

01. COMMENT: Carport addition - The applicant proposes to construct an attached Carport along the Front Perimeter yard 15 Feet from the Street property line and 6 feet from the West side yard property line. The overall wall height of the west wall is 9 feet 6" from design grade. The minimum setback based on the 9 feet 6 inches is 6 feet 4 inches, the applicant is proposing 6 from the west property line.

02. COMMENT: Workshop/Garage - The applicant proposes to construct an attached Workshop/garage along the west boundary of the property, 4 feet from the West property line. The overall wall height of the parapet from design grade is 12 feet 6 inches. The required setback is 8 feet 4 inches from the property line, the applicant is proposing 4 feet.




The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

03. COMMENT: Carport - The applicant proposes to construct an attached Carport along the Front Perimeter yard 15 Feet from the Street property line. The minimum building setback from the street perimeter yard is 20 feet. The applicant is proposing a 15 foot building setback.



The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).


04. COMMENT: Carport - The applicant proposes to construct an attached Carport along the Front Perimeter yard 15 Feet from the Street property line with a driveway length of 15 feet. The minimum driveway length from the property line is 18 feet.
02/10/2015 DRIVERA1 ENGINEERING REVIEW Needs Review
02/10/2015 DAVID RIVERA NPPO REVIEW Needs Review
02/10/2015 DRIVERA1 BUILDING-RESIDENTIAL REVIEW Needs Review