Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T15CM00347
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2015 | JASON GREEN | ENGINEERING | REVIEW | Approved | January 28, 2015 FLOODPLAIN USE PERMIT NO.: T15OT00076 ADDRESS: 2301 E Greenlee Rd Tucson Arizona 85719 PROPERTY OWNER: Andrea Matheson The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1693L, specifically described as: A portion of Parcel 113-05-008C For the purpose of a remodel (bedroom, bathroom, and kitchen) to an existing non-conforming structure. In reviewing this Floodplain Use Permit application for improvements to an existing floodprone structure, it has been concluded that the cumulative value of proposed improvements for this project to this structure, as supported by documentation provided by the applicant, is less than 50% of the current value of the existing structure. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 11 conditions: 1) All improvements proposed under this permit will be cumulative in percentage, to include this project. 2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value. 3) A building valuation was provided showing that the improvements are less than 50 % (estimate was 18.9%) of the Assessed Value ($211,094), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it. 4) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 5) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times. 6) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval. 7) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance. 8) The associated improvements are with permit activity number T15CM00347. 9) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents. 10) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives. 11) This permit is specific to the improvements for 2301 E Greenlee Rd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: William Cassidy ADDRESS: 9008 E Chickamauga St Tucson, Arizona 85710 PHONE: 520-400-1360 (EXPIRATION DATE) Month: 01 Day: 28 Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 02/02/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 2-3-15 Activity: T15CM00347 Address: 2301 E. Greenlee Rd Applicant: William Cassidy This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code and local amendments. In order to facilitate a shorter back check time, we request that you provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: 1. The engineer of record must seal the building plans, ARS 32-125. FLOOR PLAN: 2. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R302.5.1. STRUCTURAL / FRAMING PLAN: 3. Specify the connection of the existing ledger to the wall for justification of support for new floor beam, R802.1. 4. Clarify the header size over the kitchen window. The plan layout specifies a double 2x10 and the keynote indicates a triple 2x6. PLUMBING PLAN: 5. Show the size and location of all cleanouts at the junction of building drain to building sewer. Two-way cleanouts are required within 2' from the building, P3005.2. 6. Hose bibs are calculated at 2.5 FU each. Correct the fixture demand schedules accordingly, Table P2903.6. 7. Include the additional shower in the master bathroom on the fixture unit schedule. ELECTRICAL PLAN: 8. Provide minimum 3/32" lettering per Unified Development Code. 9. Provide a GFCI protected receptacle and a switched source of light for the attached garage, E3901.9, E3902.2, E3903.3. 10. The receptacle located near the wet bar in the den may not share the bathroom circuit, E3703.4, E3901.6. OUTDOOR LIGHTING CODE 11. The outdoor lighting calculation indicates (5) unshielded fixtures yet the notes specify all exterior lighting to be fully shielded, clarify. 12. Specify the shielding type for lighting fixture 'C'. All other fixtures are assumed to be unshielded (non-FCO style) 104.2. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/04/2015 | CPIERCE1 | OUT TO CUSTOMER | Completed |