Permit Number: T15CM00317
Parcel: 126160450

Address:
155 S PALOMAR DR

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T15CM00317
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2015 MICHAEL ST. PAUL ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T15CM00317
155 South Palomar Drive
Carport conversion to family room and carport addition to SFR
Five bedrooms on site with three parking spaces (UDC Section 4.9.7.B.7)


TRANSMITTAL: March 5, 2015


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The height of the structure's wall facing the north property line is twelve (12) feet. The minimum setback to the north property line is eight (8) feet. The proposed setback is six (6) feet.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). The proposed setback is nine (9'-0") to the front property line.

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). The proposed setback and driveway length is also nine (9) feet at the closest point.
03/05/2015 LOREN MAKUS ENGINEERING REVIEW Approved
03/05/2015 MICHAEL ST. PAUL NPPO REVIEW Passed
04/09/2015 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed