Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T15BU00407
Parcel: 140192770

Address:
5418 S PARK AV

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T15BU00407
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
03/20/2017 PAUL BAUGHMAN ENGINEERING REVIEW Approved The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Alvernon Wash delineation, specifically described as:

A portion of Parcel 140-19-277A, Rio Viejo Apts BLK 1 SQ20133580252 & N10' S1855' W377' E422' W2 SW4 5.26 AC SEC 6-15-14

For the purpose of constructing an 8' high CMU block wall.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 9 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the CMU block wall, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of a CMU block wall within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved site plan sheets for the construction of the an 8' high CMU block wall, which are made part of this permit.
4) The CMU wall must be constructed with drainage vents in the wall or per the legend on the site plan.
5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T17OT00294 FOR INFORMATION PLEASE CALL 791-5550."
6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
8) See the associated activity T15BU00407
9) This permit is specific to the improvements for 5418 S Park Av as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.
03/20/2017 ANDREW CONNOR ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/20/2017 MMENDIB1 OUT TO CUSTOMER Completed