Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T14PI00004
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/01/2014 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. Please include a response letter with the next submittal that states how all comments have been addressed and resubmit the original redline set of plans for back checking purposes. The current plans to meet Traffic Eng. requirements will need a Signing & Striping Sht. with Notes. Other considerations will be: - the Placita Rio De Vidrio street width will require NP conditions as will the cul-de-sacs. - STOP bar and sign along with St. Name Signs for the Placita Rio De Vidrio & Bear Canyon Rd. intersection - oblit of the Striped Bk. lane across Placita Rio De Vidrio and the creation of 50' of WG6 on the approach to that new street - a W-bound 25mph Speed limit sign - new placement of "leaving" and "entering" City limits signs Please do email me at Matthew.Geweke@tucsonaz.gov with a PDF of redlines and the corrected Shts with the revisions of these requested changes so we can expedite the Traffic Eng. acceptance/approval of these plans. I can also be reached at 791-4259 x76665 with any questions. Thanks |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 05/01/2014 | BESPINO1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 05/02/2014 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | No landscape plan submitted. If you intend to do any landscaping in the ROW please resubmit. Has NPPO been submitted and approve at DSD? |
| 05/12/2014 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | May 12, 2014 SUBJECT: Ghost River Ranch PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal reference PIA activity number on all correspondences. 1. Include the plan number "I-2014-003" in the title block of each sheet. 2. Include Development Services Department PIA activity number "T14PI00004 on cover sheet. 3. Include all lines and symbols used in drawing in legend. 4. Indicate the placement of a survey monument at the intersection Bears Canyon Rd and Placita Rio de Virdio. 5. Sheet 3, Detail A: Provide a thickened pavement edge per MAG Standard 201, Type A or Type B. 6. Address comments on redline plan set. Responses can be noted on redline drawings. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 05/14/2014 | BESPINO1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 05/14/2014 | BESPINO1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 06/04/2014 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approv-Cond | We have reviewed this plan and have the following comments: Sheet 1 - Note 38 - Change Median Island Section phone number to 791-3154 and Paul Rosenboom's office number to 837-6796. No further comments. Lance Peterson, P.E. Streets and Traffic Maintenance (520) 837-6777 |
| 06/04/2014 | IMEDINA1 | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Denied | |
| 06/12/2014 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |