Plan Number: T14PI00002
Parcel: Unknown

Address:
642 S WILMOT RD

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T14PI00002
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2014 GARY WITTWER DOT LANDSCAPE REVIEW Approved
02/03/2014 JOSE ORTIZ DOT TRAFFIC REVIEW Denied PLAN #: U-2014-003
ACTIVITY NUMBER: T14pi00002
PROJECT NAME: Lots 8-14 Block - Paving Plan
PROJECT ADDRESS: 642 S Wilmot Rd at Eli St
PROJECT REVIEWER: Matthew Geweke / Traffic Eng. Ofc: 837-6665

Resubmittal Required:
Traffic Engineering does not recommend approval these plans at this time. Plan is required for re-submittal.

The following items must be revised or added to the plan. Please include a brief response letter with the next submittal that states how all comments have been addressed.

The following items must be addressed on the plans:

1. The existing signs along both Wilmot & Eli need to be located and called out on the plans.

2. The paved alley is called out as a "one way" roadway condition, therefore the appropriate signage needs to support the plan.

If you wish to email me Matthew.Geweke@tucsonaz.gov with PDF's of the revised plan sheets of the required changes prior to the next submittal, we could expedite the Traffic Eng. acceptance of these plans.
02/07/2014 IMEDINA1 UTILITY CLEARANCES COT STREETS DIVISION Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES PC WASTEWATER MGMT Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES QUEST COMMUNICATION Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES COX COMMUNICATION Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES SOUTHWEST GAS CORP Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES EL PASO NATURAL GAS Approved
02/07/2014 IMEDINA1 UTILITY CLEARANCES KINDER MORGAN ENERGY Approved
02/13/2014 RICHARD LEIGH DOT ENGINEERING REVIEW Denied February 13, 2014


SUBJECT: Paving Plans for Lots 8 - 14, BK 10 PG 93 M&P

PROJECT REVIEWER: Richard Leigh - TDOT Permits Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal.

1. Include the plan number "U-2014-003" in the title block of each sheet.

2. Include Development Services Department PIA activity number "T14PI00002"on cover sheet.

3. Sheet 1 of 2: Use City of Tucson title blocks.

4. Provide a copy of the variance letter for allowing primary access form alley.

5. Include all lines and symbols in legend.

6. Sheet 2 of 2: Provide a centerline profile.

7. Sheet 2 of 2: Show sight visibility triangles at alley connections at Wilmot Rd and Eli Street.

8. Sheet 2 of 2: The one way alley should be changed from south to north to have traffic exit at Wilmot Rd or preferably Tampico Ave.

9. Sheet 2 of 2: Provide a cross section of alley.

10. Sheet 2 of2: Indicate asphalt mix number.

11. Provide a thickened edge along pavement edges.

12. Indicate the limits of proposed pavement.

13. Provide driveway aprons at Eli St and possibly Tampico Ave.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6646 or at Richard.leigh@tucsonaz.gov
02/19/2014 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied We have reviewed this plan and have the following comments:

1. Sheet 1 - Please provide a Streets and Traffic Maintenance signature block.
2. Sheet 1 - General Note 9 - Median Island new phone number is 791-3154 and Paul Rosenbooms new phone number is 837-6796.
3. Is this alley to be maintained by the City or with the homeowners be responcible?
4. Sheet 2 - Station 11+50 - It appears that this will convey drainage. Is there a plan to stabilize this area with regards to erosion?
5. Sheet 2 - What is the expected stormwater runoff for this alley?
6. Is the alley to be crowned or inverted?
7. Sheet 2 - Station 17+50 - Pavements seems to stop short of tying in to existing pavement. Please extend the asphalt to tie in.

No further comments.
Marc

Lance Peterson
Streets and Traffic Maintenance
02/27/2014 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
02/27/2014 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed