Permit Number: T14OT00288
Parcel: 11504263A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T14OT00288
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/10/2015 JASON GREEN ENGINEERING REVIEW Approved March 25, 2015
FLOODPLAIN USE PERMIT NO.: T14OT00288
ADDRESS: 307 E Helen St Tucson, Arizona 85705
PROPERTY OWNER: Tucson Chinese Christian Fellowship

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the Mabel Street Wash, specifically described as:

A portion of Parcel 115-04-263A

For the purpose of constructing a new Sanctuary Building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 10 conditions:

1) This project is located in a mapped regulatory floodplain per the "Approximate Flood Hazard Areas along Mabel Street from Cherry Avenue to I10," April 2007 delineations per the Drainage Statement prepared by JE Fuller Hydrology and Geomorphology. With Drainage Statement Addendum per CMG Drainage Engineering, Inc., 20DEC13 for site specific information.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) For purposes of this permit the following flood elevations shall be used for the building:
Base Flood Elevation (BFE) = 2387.49 feet NGVD 1929 (FFE is based off of NGVD29 Datum)
Regulatory Flood Elevation (RFE) = 2388.49 feet NGVD 1929 (FFE is based off of NGVD29 Datum)
Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE).

4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the building as well as the identity and location of all other equipment/machinery servicing the building.

5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T14OT00288 FOR INFORMATION PLEASE CALL 791-5550."

6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

7) All work shall conform to the approved building plan, T14CM01441, which is made part of this permit.

8) This permit also covers the demolition of the existing SFR as per the approved demo plan, T15BU00496, which is made part of this permit.

9) The floodplain use permit also covers the vehicular use area improvements as shown on the development plan package, DP14-0040, as part of the project. The development plan package is to be used as the site construction document.

10) This permit is specific to the improvements for 307 E Helen St as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Tom Kirschner
ADDRESS: PO Box 90676 Tucson, Arizona 85752
PHONE: 520-318-3400
OWNER: Tucson Chinese Christian Church
ADDRESS: 307 E Helen St Tucson, AZ 85705
PHONE: 520-792-1374

(EXPIRATION DATE) Month: 03 Day: 25 Year: 2016

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/29/2015 JGREEN2 APPROVAL SHELF Completed
07/29/2015 JGREEN2 OUT TO CUSTOMER Completed
07/29/2015 JGREEN2 REJECT SHELF Completed