Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM08917
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/17/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 4-21-15 Activity: T14CM08917 Address: 5433 S Madison #2 Applicant: Jesus Antonio Jauregui This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code and local amendments. In order to facilitate a shorter back check time, we request that you provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Specify the location of all utility lines and service meters including those supplying the existing building, R106.1.1. 2. Pencil and/or white-out corrections are not acceptable on final plan set. INCLUSIVE HOME DESIGN: 3. Specify the location of sidewalks or other means of communication between the accessible route and the public way, A117.1-1003.2. FLOOR PLAN: 4. Show the location of the attic access in a hallway or other readily accessible location, R807. STRUCTURAL / FRAMING PLAN: 5. Clarify the support of openings in masonry walls. Wood headers may not support masonry, R606.10. Provide cross section detail if wood headers will be used as indicated on sheet 4 to verify sufficient bearing and clearance, R317.1(4) R606.14. 6. The Manual J calculations provided indicate radiant barrier sheathing for the roof assembly. This material requires an air space adjacent to the foil surface yet the plan indicates that the insulation will be tight to the roof sheathing. Clarify proposed roof assembly. 7. Condensation control is required for the unvented roof assembly method. Specify an air-impermeable rigid insulation material sealed tight to the roof sheathing or spray applied closed cell foam to a minimum value of R5 if an unvented assembly will be utilized, R806.5. 8. The section details indicate vented frieze boards yet there does not appear to be a ventilated space. Clarify what is being ventilated. ELEVATIONS: 9. Show the mechanical unit and its working platform on the elevation drawings, M1305.1. PLUMBING PLAN: 10. Specify accurate water conservation requirements: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2. 11. Provide a black water connection to the clothes washing machine. Note: The configuration provided would not require a connection to the gray water line. A gray water discharge from the washing machine is optional in this case, Ordinance #11089. 12. Clarify how the temperature and pressure relief line will discharge above grade. The location of the line is shown in a wall that has a door in it, P2803.6.1. 13. Specify the maximum developed length of gas piping from the meter to the furthest appliance, G2413.1, Table G2413.4 (1). MECHANICAL PLAN: 14. Include the make and manufacturer of the HVAC equipment on sheet 8. ELECTRICAL PLAN: 15. All outlets specified in section E3902.12 shall be protected with combination-type arc-fault breakers (not just bedroom outlets). 16. Include a bond to the proposed gas piping on the riser diagram, E3607/8. 17. Specify faceplate grounding per E4001.11.1. 18. Specify tamper resistant receptacles per E4002.14. If you have any questions please contact: Clayton Trevillyan, CBO 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/23/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |